This pilot study tested Whisper and WhisperX on standardized medical recordings from native and non-native English speakers and found much higher error rates for non-native speakers. Adding a GPT-4o correction step cut word error rates by up to 6.9% and nearly eliminated accent-related disparities. The chained ASR–LLM pipeline boosts transcription accuracy across diverse clinical speakers.
- Whisper and WhisperX both show significantly higher word error rates for non-native English speakers on clinical scripts, with Whisper's gap being larger.
- Complex terminology in cardiology/pulmonology scripts hit accuracy hardest, dropping NER precision and F1 for non-native speech.
- Piping WhisperX output through GPT-4o for correction cut WER by up to 6.9% and nearly closed the native/non-native accuracy gap.
- With ~1 in 5 US healthcare workers foreign-born, uncorrected ASR bias risks misrecorded diagnoses or medication names in AI scribe tools.